100% Updated EMC DES-1241 Enterprise PDF Dumps [Q40-Q60]

Share

100% Updated EMC DES-1241 Enterprise PDF Dumps

Use Valid Exam DES-1241 by PremiumVCEDump Books For Free Website

NEW QUESTION 40
What is the last step when adding a drive to a Dell EMC PowerStore system?

  • A. Backup the keystore
  • B. Add the drive to the pool
  • C. Zero the drive
  • D. Verify the new drive is seen

Answer: D

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/install-a-25- drive?guid=guid-bddae51e-a561-4e84-bc0a-c2e99a43f033&lang=en-us

 

NEW QUESTION 41
Which port is used to SSH from one Dell EMC PowerStore appliance to another?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Explanation/Reference: https://topics-cdn.dell.com/pdf/pwrstr-scg_en-us.pdf

 

NEW QUESTION 42
Which account credentials are needed to run diagnostic commands?

  • A. root
  • B. console
  • C. admin
  • D. service

Answer: D

 

NEW QUESTION 43
Which LED combination shows a connected and working node?

  • A. power LED: steady green fault LED: amber
  • B. power LED: blinking green fault LED: blue
  • C. power LED: blinking green fault LED: off
  • D. power: LED: steady green fault LED: off

Answer: D

 

NEW QUESTION 44
What is achieved when the Rapid Spanning Tree Protocol (RSTP) is enabled on a Dell EMC PowerStore network configuration?

  • A. Redundant connectivity between data switches
  • B. Communication between data switches and management switch on PowerStore T
  • C. Management between appliance and vCenter on PowerStore X
  • D. Fault tolerance between appliances in a PowerStore cluster

Answer: C

 

NEW QUESTION 45
When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B.

Answer:

Explanation:

Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/cable-the-base-enclosure-to- the-expansion-enclosure?guid=guid-d68d049f-2b77-489f-b1ab-553f4f3de8aa&lang=en-us

 

NEW QUESTION 46
What are the recommended number of network switches in a Dell EMC PowerStore T environment?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/ powerstore-t-model-appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us

 

NEW QUESTION 47
Through which network do external hosts connect to the cluster for data access?

  • A. ICD
  • B. Management
  • C. ICM
  • D. Storage

Answer: D

Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf

 

NEW QUESTION 48
What is the maximum number of base enclosures in a cluster when planning a Dell EMC PowerStore T installation?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Explanation/Reference: https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell- emc-powerstore-platform-introduction.pdf

 

NEW QUESTION 49
Refer to the exhibit.

What Dell EMC PowerStore ToR front-end cabling is shown?

  • A. OOB Management
  • B. Management and discovery
  • C. VLTi interconnectivity
  • D. Core switch uplink

Answer: C

 

NEW QUESTION 50
A Storage Administrator has just installed PSTCLI on a Linux client. The administrator is unfamiliar with the PSTCLI command list. How can the administrator get a list of all PSTCLI commands from the cli> prompt?

  • A. Type the <Ctrl>+keys together
  • B. Press the <Tab> key
  • C. Use the show all command
  • D. Use the help all command

Answer: B

 

NEW QUESTION 51
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?

  • A. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
  • B. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
  • C. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
  • D. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations

Answer: C

 

NEW QUESTION 52
A Storage Administrator encounters a Snapshot issue on a Dell EMC PowerStore X system.
The administrator engages support and they determine the Snapshot issue is a known code bug within the OS version of PowerStore code. How can support address the problem in a timely manner?

  • A. Disable the Snapshots feature to avoid encountering the code bug
  • B. Upgrade the PowerStore with a hotfix that corrects the code bug
  • C. Upgrade the Snapshot portion of code within the OS
  • D. Wait for a new full OS release that corrects the code bug

Answer: B

 

NEW QUESTION 53
What is a step in configuring the ToR data switches for a Dell EMC PowerStore X?

  • A. Create VLANs for NAS servers
  • B. Configure a port for the discovery laptop
  • C. Configure LACP uplink to management switch
  • D. Create node A port-channel

Answer: B

 

NEW QUESTION 54
From where can a data collection be initiated within Dell EMC PowerStore Manager?

  • A. Cluster, appliance, and alerts
  • B. Node, storage resource, and alerts
  • C. Appliance, node, and storage resource
  • D. Cluster, appliance, and event log

Answer: A

Explanation:
Collecting Support Materials can be initiated several ways from PowerStore Manager. Data Collections can be started at the Cluster, Appliance, Storage Resource, and Alerts level.

 

NEW QUESTION 55
When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 56
Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 57
Refer to the exhibit.

What is the result of the network configuration shown for a Dell EMC PowerStore T?

  • A. Ports 1/1/55 and 1/1/56 are added to the VLTi domain
  • B. Interfaces are configured for PowerStore discovery traffic
  • C. Ports 1/1/55 and 1/1/56 are added to a new LACP domain
  • D. Interfaces are configured for remote replication traffic

Answer: B

 

NEW QUESTION 58
Refer to the exhibit.

A Storage Administrator noticed a solid amber LED. What does this mean?

  • A. Drive rebuilding
  • B. Drive faulted
  • C. Power up
  • D. Drive identification on

Answer: B

Explanation:
Reference:
https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en

 

NEW QUESTION 59
What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

  • A. USB stick inserted into the system
  • B. Data Collect using vCenter
  • C. Discovery Utility
  • D. Data Collect using Service Container

Answer: D

 

NEW QUESTION 60
......

EMC DES-1241 Official Cert Guide PDF: https://pass4lead.premiumvcedump.com/EMC/valid-DES-1241-premium-vce-exam-dumps.html